What size / gauge / length wiring is used for power wires on the Velit Air Conditioner Units?
Velit AC Power Wire AWG depends on if the unit is 12v/24v/48v but also the distance the wire is ran.
Below is a list of the stock power harness wire AWG sizes for the various AC units we offer in various voltages. IMPORTANT: It should be noted that if our stock harnesses are extended that larger AWG should be used according to calculated standards to prevent amperage loss over distance. Consult an electrical engineer or utilize online calculators to ensure proper wire size for safety and proper function of the unit.
NOTE: We use Metric MM2 so AWG below is for reference, rather than exact.
2000R
15ft wiring harness with in-line fuse and Andersen connector on the unit side and Ring connectors on the Supply side.
12V: 6AWG
24V: 8AWG
48V: 12AWG
2000R MINI
15ft wiring harness with in-line fuse and Andersen connector on the unit side and Ring connectors on the Supply side.
12V: 6AWG
48V: 12AWG
2000U (Underbench)
11.5ft (3.5 meters) wiring harness with in-line fuse and Andersen connector on the unit side and Ring connectors on the supply side. Also includes two block style connectors for optional ring to ring style connection.
12V: 6AWG
24V: 8AWG
48V: 12AWG
3000R
15ft wiring harness with in-line fuse and Andersen connector on the unit side and Ring connectors on the Supply side.
24V: 8AWG
48V: 12AWG